language en

The ENSNARE intervention ontology

This version:
https://ensnare.nobatek.com/intervention/0.1
Latest version:
https://ensnare.nobatek.com/intervention#
Contributors:
Pierre Bourreau
Download serialization:
JSON-LD RDF/XML N-Triples TTL
License:
http://insertlicenseURIhere.example.org
Visualization:
Visualize with WebVowl
Cite as:
The ENSNARE intervention ontology. Retrieved from: https://ensnare.nobatek.com/intervention/0.1

Ontology Specification Draft

Abstract

This is a placeholder text for the abstract. The abstract should contain a couple of sentences summarizing the ontology and its purpose.

Introduction back to ToC

This is a place holder text for the introduction. The introduction should briefly describe the ontology, its motivation, state of the art and goals.

Namespace declarations

Table 1: Namespaces used in the document
[Ontology NS Prefix]<https://ensnare.nobatek.com/intervention#>
bldg<https://ensnare.nobatek.com/building#>
owl<http://www.w3.org/2002/07/owl#>
proj<https://ensnare.nobatek.com/project#>
rdf<http://www.w3.org/1999/02/22-rdf-syntax-ns#>
rdfs<http://www.w3.org/2000/01/rdf-schema#>
terms<http://purl.org/dc/terms/>
xml<http://www.w3.org/XML/1998/namespace>
xsd<http://www.w3.org/2001/XMLSchema#>

The ENSNARE intervention ontology: Overview back to ToC

This ontology has the following classes and properties.

Classes

Object Properties

Data Properties

Named Individuals

The ENSNARE intervention ontology: Description back to ToC

The ENSNARE intervention ontology describes different actions that can be performed for an energy renovation. Actions are either generic (i.e. can be performed in any or in standards energy renovation programs), or ENSNARE specific (i.e. installing off-site façade modules that incorporate active energy renewable systems

Cross-reference for The ENSNARE intervention ontology classes, object properties and data properties back to ToC

This section provides details for each class and property defined by The ENSNARE intervention ontology.

Classes

central heat pumpc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#CentralHeatPump

has super-classes
Heat Pump c
is also defined as
named individual

ENSNARE hybrid PV+T panelc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_PVT

has super-classes
Generic ENSNARE active product c
is in domain of
electricity production performance factor dp, thermal production performance factor dp
is also defined as
named individual

ENSNARE PV panelc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_PV

has super-classes
Generic ENSNARE active product c
is in domain of
electricity production performance factor dp
is also defined as
named individual

ENSNARE solar thermal panelsc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_ST

has super-classes
Generic ENSNARE active product c
is in domain of
thermal production performance factor dp
is also defined as
named individual

Generic ENSNARE active productc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_Product

has sub-classes
ENSNARE PV panel c, ENSNARE hybrid PV+T panel c, ENSNARE solar thermal panels c

individual heat pumpc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#IndividualHeatPump

has super-classes
Heat Pump c
is also defined as
named individual

renovation actionc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#RenovationAction

A renovation action is a refinement of a recommendation. It specifies the type of product to use
has members
ENSNARE 10cm ni, ENSNARE 20cm ni, ENSNARE 30cm ni, ENSNARE no insulation ni, ETI PVC 10cm ni, ETI PVC 15cm ni, ETI PVC 20cm ni, ETI PVC 30cm ni, ETI PVC 44cm ni, ETI PVC 5cm ni, Heat Pump ni, Insulation Roof XPS 10cm ni, Insulation Roof XPS 15cm ni, Insulation Roof XPS 18cm ni, Insulation Roof XPS 22cm ni, Insulation Roof XPS 30cm ni, Insulation Roof XPS 45cm ni, Insulation Roof XPS 60cm ni, PV installation - Roof ni, active windows ni, double-glazed windows ni, dual flow ventilation ni, wlassic windows ni

Surface needed for a PV installationc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#Facade_needed_PV

has super-classes
Surface needed for a solar system installation c

Surface needed for a PV+T installationc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#Facade_needed_PVT

has super-classes
Surface needed for a solar system installation c

Surface needed for a solar system installationc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#Facade_Needed_Solar

has sub-classes
Surface needed for a PV installation c, Surface needed for a PV+T installation c, Surface needed for an ST installation c
is in domain of
facade op, needed surface dp

Surface needed for an ST installationc back to ToC or Class ToC

IRI: https://ensnare.nobatek.com/intervention#Facade_needed_ST

has super-classes
Surface needed for a solar system installation c

Object Properties

facadeop back to ToC or Object Property ToC

IRI: https://ensnare.nobatek.com/intervention#facade

surface distribution of the façade surface per active systems.

scenarioop back to ToC or Object Property ToC

IRI: https://ensnare.nobatek.com/intervention#scenario

renovation of a façade as part of an ENSNARE renovatoin scenario
has domain
facade c
has range
ensnare scenario c

Data Properties

COP - Coefficient of Performancedp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#COP

has domain
Heat Pump c
has range
double
is also defined as
named individual

electricity production performance factordp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#elecPerf

ENSNARE PV installation surfacedp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#PV_surface

has domain
reno scenario c
has range
double
is also defined as
named individual

ENSNARE PV+T installation surfacedp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#PVT_surface

has domain
reno scenario c
has range
double
is also defined as
named individual

ENSNARE Solar Thermal installation surfacedp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#ST_surface

has domain
reno scenario c
has range
double
is also defined as
named individual

needed surfacedp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#needed_surface

has domain
Surface needed for a solar system installation c
has range
double
is also defined as
named individual

thermal production performance factordp back to ToC or Data Property ToC

IRI: https://ensnare.nobatek.com/intervention#thermalPerf

Named Individuals

active windowsni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_ActiveWindows

belongs to
renovation action c

central heat pumpni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#CentralHeatPump

has facts
COP - Coefficient of Performance dp "4.5"^^decimal
is also defined as
class

change windowsni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ChangeWindows

Renovation recommendation to change the windows
belongs to
recommendation passive c

COP - Coefficient of Performanceni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#COP

belongs to
datatype property c
is also defined as
data property

domestic hot waterni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#DomesticHotWater

Renovation recommendation to change the domestic hot water system
belongs to
recommendation active c

double-glazed windowsni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#DoubleGlazedWindows

belongs to
renovation action c

dual flow ventilationni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#DualFlowVentilation

belongs to
renovation action c

ENSNARE 10cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_10cm

ENSNARE-integrated external thermal insulation of the façade with a thickness of 10cm.
belongs to
renovation action c

ENSNARE 20cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_20cm

ENSNARE-integrated external thermal insulation of the façade with a thickness of 20cm.
belongs to
renovation action c

ENSNARE 30cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_30cm

ENSNARE-integrated external thermal insulation of the façade with a thickness of 30cm.
belongs to
renovation action c

ENSNARE hybrid PV+T panelni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_PVT

has facts
electricity production performance factor dp "0.18"^^decimal
thermal production performance factor dp "0.58"^^decimal
is also defined as
class

ENSNARE no insulationni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_None

belongs to
renovation action c

ENSNARE PV installation surfaceni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#PV_surface

belongs to
datatype property c
is also defined as
data property

ENSNARE PV panelni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_PV

has facts
electricity production performance factor dp "0.16"^^decimal
is also defined as
class

ENSNARE PV+T installation surfaceni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#PVT_surface

belongs to
datatype property c
has facts
electricity production performance factor dp "7.2"^^decimal
thermal production performance factor dp "2.5"^^decimal
is also defined as
data property

ENSNARE Solar Thermal installation surfaceni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ST_surface

belongs to
datatype property c
has facts
thermal production performance factor dp "4.0"^^decimal
is also defined as
data property

ENSNARE solar thermal panelsni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_ST

has facts
thermal production performance factor dp "0.84"^^decimal
is also defined as
class

ETI PVC 10cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_10cm

External thermal insulation of the façade with a thickness of 10cm. The material used is polystyrene
belongs to
renovation action c

ETI PVC 15cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_15cm

External thermal insulation of the façade with a thickness of 15cm. The material used is polystyrene
belongs to
renovation action c

ETI PVC 20cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_20cm

External thermal insulation of the façade with a thickness of 20cm. The material used is polystyrene
belongs to
renovation action c

ETI PVC 30cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_30cm

External thermal insulation of the façade with a thickness of 30cm. The material used is polystyrene
belongs to
renovation action c

ETI PVC 44cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_44cm

External thermal insulation of the façade with a thickness of 44cm. The material used is polystyrene
belongs to
renovation action c

ETI PVC 5cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ETI_PVC_5cm

External thermal insulation of the façade with a thickness of 5cm. The material used is polystyrene
belongs to
renovation action c

Heat Pumpni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#HeatPump

belongs to
renovation action c
is also defined as
class

heatingni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Heating

Renovation recommendation to change the heating system
belongs to
recommendation active c

individual heat pumpni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#IndividualHeatPump

has facts
COP - Coefficient of Performance dp "4.5"^^decimal
is also defined as
class

install p vni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#InstallPV

Renovation recommendation to install some PV panels
belongs to
recommendation active c

insulate facadeni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#InsulateFacade

Renovation recommendation to insulate the façade
belongs to
recommendation passive c

insulate roofni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#InsulateRoof

Renovation recommendation to insulate the roof
belongs to
recommendation passive c

Insulation Roof XPS 10cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_10cm

belongs to
renovation action c

Insulation Roof XPS 15cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_15cm

belongs to
renovation action c

Insulation Roof XPS 18cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_18cm

belongs to
renovation action c

Insulation Roof XPS 22cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_22cm

belongs to
renovation action c

Insulation Roof XPS 30cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_30cm

belongs to
renovation action c

Insulation Roof XPS 45cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_45cm

belongs to
renovation action c

Insulation Roof XPS 60cmni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Insulation_Roof_XPS_60cm

belongs to
renovation action c

needed surfaceni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#needed_surface

belongs to
datatype property c
is also defined as
data property

PV installation - Roofni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#PV_Roof

belongs to
renovation action c
has facts
electricity production performance factor dp "0.2"^^decimal

ventilationni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#Ventilation

Renovation recommendation to install or change the ventilation system
belongs to
recommendation active c

wlassic windowsni back to ToC or Named Individual ToC

IRI: https://ensnare.nobatek.com/intervention#ENSNARE_ClassicWindows

belongs to
renovation action c

Legend back to ToC

c: Classes
op: Object Properties
dp: Data Properties
ni: Named Individuals

References back to ToC

Add your references here. It is recommended to have them as a list.

Acknowledgments back to ToC

The authors would like to thank Silvio Peroni for developing LODE, a Live OWL Documentation Environment, which is used for representing the Cross Referencing Section of this document and Daniel Garijo for developing Widoco, the program used to create the template used in this documentation.